Home

On application of low doses from beta radiation source in OSL retrospective dosimetry

Repozytorium Uniwersytetu Mikołaja Kopernika

Pokaż prosty rekord

dc.contributor.author Przegiętka, Krzysztof
dc.contributor.author Chruścińska, Alicja
dc.date.accessioned 2014-06-17T07:07:29Z
dc.date.available 2014-06-17T07:07:29Z
dc.date.issued 2014-05
dc.identifier.citation Radiation Physics and Chemistry, DOI information: 10.1016/j.radphyschem.2014.05.045
dc.identifier.issn 0969-806X
dc.identifier.uri http://repozytorium.umk.pl/handle/item/1913
dc.description Poster zaprezentowany na miedzynarodowej konferencji naukowej 1st International Conference on Dosimetry and its Applications, Prague, Czech Republic, 23-28 June 2013; w formie artykułu, po recenzjach został przyjęty do druku w Radiation Physics and Chemistry (2014); DOI: 10.1016/j.radphyschem.2014.05.045
dc.description.abstract The paper reports on three levels of dose rates obtainable from single beta source: (133±3) mGy/s, (17.8±0.3) mGy/s and (1.94±0.04) mGy/s, as calibrated for quartz sand grains. These values were achieved for different attenuation stages of beta radiation emitted by standard Sr-90/Y-90 source with the nominal activity of 1.48 GBq attached to an automatic luminescence reader. Lower dose rates give opportunity for exact dosing, which is especially required in luminescence dating applied to young samples as well as in environmental dosimetry. Moreover new method for determining time lag in opening the source in the Riso beta irradiator is presented. This allowed to resolve the contradiction appearing in the literature. The time delay was found to be (0.15±0.01) s per single irradiation. For improving accuracy the dose rate correction is suggested to be taken into account for irradiations shorter than 30 seconds.
dc.description.sponsorship NCN
dc.language.iso eng
dc.publisher Elsevier B.V.
dc.rights Attribution-ShareAlike 3.0 Poland
dc.rights info:eu-repo/semantics/openAccess
dc.rights.uri http://creativecommons.org/licenses/by-sa/3.0/pl/
dc.subject Luminescence dosimetry system
dc.subject Dose rate calibration
dc.subject Retrospective dosimetry
dc.subject Beta radiation source
dc.title On application of low doses from beta radiation source in OSL retrospective dosimetry
dc.type info:eu-repo/semantics/article


Pliki:

Z pozycją są związane następujące licencje:

Należy do następujących kolekcji

Pokaż prosty rekord

Attribution-ShareAlike 3.0 Poland Ta pozycja jest udostępniona na licencji Attribution-ShareAlike 3.0 Poland