A novel stress sensor enables accurate estimation of microscale tissue mechanics in quantitative micro-elastography

dc.contributor.authorMetzner, Kai L.
dc.contributor.authorFang, Qi
dc.contributor.authorSanderson, Rowan W.
dc.contributor.authorYeow, Yen L.
dc.contributor.authorGreen, Celia
dc.contributor.authorAbdul-Aziz, Farah
dc.contributor.authorHamzah, Juliana
dc.contributor.authorMowla, Alireza
dc.contributor.authorKennedy, Brendan F.
dc.date.accessioned2026-07-30T11:25:40Z
dc.date.issued2024-09
dc.descriptionThis study was supported by the Australian Research Council; the Department of Health, Western Australia; the Australian Government Research Training Program Scholarship; and The University of Western Australia University Postgraduate Award. B.F.K. acknowledges funding from the NAWA Chair programme of the Polish National Agency for Academic Exchange and from the National Science Centre, Poland, grant numer 2023/02/1/ST2/00002.
dc.description.abstractQuantitative micro-elastography (QME) is a compression-based optical coherence elastography technique enabling the estimation of tissue mechanical properties on the micro-scale. QME utilizes a compliant layer as an optical stress sensor, placed between an imaging window and tissue, providing quantitative estimation of elasticity. However, the implementation of the layer is challenging and introduces unpredictable friction conditions at the contact boundaries, deteriorating the accuracy and reliability of elasticity estimation. This has largely limited the use of QME to ex vivo studies and is a barrier to clinical translation. In this work, we present a novel implementation by affixing the stress sensing layer to the imaging window and optimizing the layer thickness, enhancing the practical use of QME for in vivo applications by eliminating the requirement for manual placement of the layer, and significantly reducing variations in the friction conditions, leading to substantial improvement in the accuracy and repeatability of elasticity estimation. We performed a systematic validation of the integrated layer, demonstrating >30% improvement in sensitivity and the ability to provide mechanical contrast in a mechanically heterogeneous phantom. In addition, we demonstrate the ability to obtain accurate estimation of elasticity (<6% error compared to <14% achieved using existing QME) in homogeneous phantoms with mechanical properties ranging from 40 to 130 kPa. Furthermore, we show the integrated layer to be more robust, exhibiting increased temporal stability, as well as improved conformity to variations in sample surface topography, allowing for accurate estimation of elasticity over acquisition times 3 longer than current methods. Finally, when applied to ex vivo human breast tissue, we demonstrate the ability to distinguish between healthy and diseased tissue features, such as stroma and cancer, confirmed by co-registered histology, showcasing the potential for routine use in biomedical applications.
dc.description.sponsorshipThis study was supported by the Australian Research Council; the Department of Health, Western Australia; the Australian Government Research Training Program Scholarship; and The University of Western Australia University Postgraduate Award. B.F.K. acknowledges funding from the NAWA Chair programme of the Polish National Agency for Academic Exchange and from the National Science Centre, Poland, grant numer 2023/02/1/ST2/00002.
dc.identifier.citationAPL Bioeng. 8, 2024, 036115
dc.identifier.otherhttps://doi.org/10.1063/5.0220309
dc.identifier.urihttps://repozytorium.umk.pl/handle/item/7351
dc.language.isoeng
dc.publisherAIP Publishing
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subjectElastic stiffness
dc.subjectElastic modulus
dc.subjectViscoelasticity
dc.subjectCoherence imaging
dc.subjectOptical imaging
dc.subjectCancer biomarkers
dc.subjectTactile Imaging
dc.subjectMedical imaging
dc.subjectHistology
dc.subjectTissue diagnostics
dc.titleA novel stress sensor enables accurate estimation of microscale tissue mechanics in quantitative micro-elastography
dc.typeinfo:eu-repo/semantics/article

Files

Original bundle

Loading...
Thumbnail Image
Name:
Kennedy_Novel.pdf
Size:
4.88 MB
Format:
Adobe Portable Document Format

License bundle

Loading...
Thumbnail Image
Name:
license.txt
Size:
1.34 KB
Format:
Item-specific license agreed upon to submission
Description: